VISX STAR S4 IR |
|
WAVELIGHT
ALLEGRETTO |
|
BAUSCH & LOMB |
|
LADAR VISION 4000/6000 |
|
NIDEK EC 5000 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Customized Wavefront Treatments |
|
Yes - Widest FDA approval of any laser system worldwide |
|
Limited |
|
Limited |
|
Limited |
|
No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Wavefront
Resolution |
|
Fourier algorithm
offers highest
resolution of
wavefront error |
|
Zernicke
algorithm
interpolates and
smoothes data
artificially |
|
Zernicke
algorithm
interpolates and
smoothes data
artificially |
|
Zernicke
algorithm
interpolates and
smoothes data
artificially |
|
Zernicke
algorithm
interpolates and
smoothes data
artificially |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Active 3-D Eye Tracking |
|
Yes |
|
No - 2-D only |
|
No - 2-D only |
|
No - 2-D only |
|
No - 2-D only |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Iris Registration |
|
Yes - Centers
& aligns
treatment
independent of
pupil center migration
& eye cyclorotation |
|
No - Manual
marking only -
less accurate
and subjective
|
|
No - Manual
marking only -
less accurate
and subjective |
|
No - Manual
marking only -
less accurate
and subjective |
|
No - Manual
marking only -
less accurate
and subjective |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Compensates for
pupil migration
during physiologic
pupil dilation |
|
Yes - centers
and aligns
treatment independent
of pupil
migration |
|
No |
|
No |
|
No -
Pharmacologic
pupil
dilation required
for tracking
creates potential
for centering error |
|
No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Requires
peri-operative
use of eye drops
that impair
healing |
|
No |
|
No |
|
Yes |
|
Yes |
|
No |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Size of Laser Beam |
|
Small and large
spot for rapid
treatment and
optimized to
reduce thermal
injury to tissue |
|
Small spot only
but very high
speed reduces
tissue dehydration
during laser
photoablation |
|
Small spot only
- slows treatment
and allows for
tissue dehydration
during laser
photoablation |
|
Small spot only
- slows treatment
and allows for
tissue dehydration
during laser
photoablation |
|
Scanning slit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Thermal Damage to Cornea |
|
Variable spot
scanning and
variable rep rate
reduces thermal
effects |
|
Higher speed
and excellent beam
characteristics may
reduce thermal
load to tissue |
|
High speed
and small spot
can be prone to
thermal and
drying effects
|
|
High speed
and small
Gaussian spot
prone to thermal
and drying effects |
|
Scanning slit
creates heat
that damages
tissue |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Physician choice |
|
Largest market
share in the US
and growing rapidly
(VISX invented
laser vision
correction) |
|
Limited physician
acceptance to
date |
|
Limited physician
acceptance to
date |
|
Shrinking physician
acceptance &
numerous post
market complaints
at FDA (see FDA
MAUDE database)
6000 is currently
recalled by the FDA |
|
Shrinking
physician
acceptance due
to aging
platform |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Safety in
conservation
of corneal
tissue |
|
Conservative
leaving good
residual for
strength |
|
Conservative
leaving good
residual for
strength |
|
Aggressive
system that
is often tissue
"hungry" |
|
Aggressive
system that
is often tissue
"hungry" |
|
Conservative
leaving good
residual for
strength |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enhancement
Rate |
|
Low - Typically
less than 5% |
|
Low - Typically
less than 5% |
|
Insufficient Data
Available for
Comparison |
|
Many centers
report high rates
of retreatments
from overcorrection |
|
Higher reported
rates due to
aging platform |
|
|
|
|
|
|
|
|
|
|
|
|
|
|